steam generators
Coates Offshore has an extensive fleet of steam generators providing outputs up to 5.8 million btu. Coates Offshore steam generators are ideal for well testing operations and maintenance.
A remote emergency shutdown facility is available ensuring instant safe shutdown should methane, propane and H2S gas or a similar hazard be detected or encountered.
performance
| Saturated Steam Flow | Working Pressure | Max Steam Temp | Fuel Tank | Water Tank | Fuel Consumption | Full Load Running | |||
| Mmbtu | kg/hr* | PSIG | barg | ºC | litres | litres | litres/hr | hrs | |
| CPS 4.5 Mmbtu C RS | 4.5 | 2000 | 150 | 10.34 | 186 | 1035 | 1035 | 142.7 | 7.2 |
| CPS 5.8 Mmbtu C RS | 5.8 | 2720 | 150 | 10.34 | 186 | 1035 | 1035 | 193.4 | 5.3 |
*Saturated steam output is based on a closed system installation with full hot water returns
Water consumption without returns to hot well are 2000 litres/hour (4.5Mmbtu) and 2720 litres/hour (5.8Mmbtu).
specification
| Length | Width | Height | Weights | ||
| mm | mm | mm | kg(dry) | kg(operating) | |
| CPS 4.5 Mmbtu C RS | 6058 | 2438 | 2896 | 11000 | 14000 |
| CPS 5.8 Mmbtu C RS | 6058 | 2438 | 2896 | 12000 | 17000 |
service and utility requirements
- The burner and pump require a combined power supply of ~ 90kVAs
- Power supply can be 380-440V and 50 or 60 Hz
- Coates steam generators are certified for manned operation offshore and engineer support is required for monitoring performance and refuelling and for rigging and de-rigging.